ACCURACY OF MERGING SCANS OF DEFINITIVE FIXED PROSTHODONTIC IMPRESSIONS TO OBTAIN A SINGLE DIGITIZED MASTER CAST
dc.contributor.advisor | Dr. Hongseok An | |
dc.contributor.author | OSSAMA HASSAN RAFFA | |
dc.date | 2020 | |
dc.date.accessioned | 2022-06-02T04:57:09Z | |
dc.date.available | 2022-06-02T04:57:09Z | |
dc.degree.department | Prosthodontics | |
dc.degree.grantor | Marquette University | |
dc.description.abstract | Results: The mean average error in the sample was -0.4 μm. The average upper limit of 95% confidence interval was 36.5 μm, while the average lower limit of 95% confidence interval was -37.3 μm. The mean RMS of the errors found was 18.9 μm. Conclusions: Merging digitized definitive impressions to correct marginal defects resulted in master casts with high level of accuracy relative to the standard reference. | |
dc.identifier.uri | https://drepo.sdl.edu.sa/handle/20.500.14154/61877 | |
dc.language.iso | en | |
dc.title | ACCURACY OF MERGING SCANS OF DEFINITIVE FIXED PROSTHODONTIC IMPRESSIONS TO OBTAIN A SINGLE DIGITIZED MASTER CAST | |
sdl.thesis.level | Master | |
sdl.thesis.source | SACM - United States of America |